※ Specifications:


★ Model No.: PS100/N1201SA

★ working currency: 140MHz~2700MHz

★ stepped frequency:1kHz

★ charge current: 420mA
<...

Buy Now From Amazon

※ Specifications:


★ Model No.: PS100/N1201SA

★ working currency: 140MHz~2700MHz

★ stepped frequency:1kHz

★ charge current: 420mA

★ charge port: USB

★ Auto power off can be set: 5-60minutes

★ Display: 2.4cun TFT trdp

★ Resolution ratio: 320*240(QVGA)

★ Battery Capacity: 3800 mAH (14Wh)

★ power consumption <1.5W

★ measured parameters: Resistance, Reactance,VSWR and S11

★ resolution ratio: 4 digits

★ frequency accuracy: ±10ppm

★ Connector: SMA-K

★ measurement range:

Impedance: 1 ohm ~1000 ohm (frequency<1.3GHz(Absolute value of impedance); 1 ohm ~300 ohm (frequency>1.3GHz(Absolute value of impedance)

VSWR: 1~65 (frequency<1.3GHz); 1~10 (frequency>1.3GHz) S11(dB): 0dB~-50dB



※ Boot: Press the second button and power button at the same to power on .



※This instrument has four interfaces: single point measurement, scanning, system information, correction and calibration.



※ Directivity: < 35dB (140MHz to 2GHz after calibration); < 25dB (2GHz to 2.7GHz)



※ Scanning Points: 280



※ RF Output Level: -18dBm



※ Working Temperature: 5°~ 40°



※ Atmospheric Pressure: 860hPa~1060hPa



※ Error (Single-point measurement):

★ For Impedance: < Impedance absolute value x 5%±0.1Ω (Z<200Ω, frequency<1.5GHz)

★ For S11(dB/°): 0.5dB/5°(0dB to -10dB); 1dB/10° (-10dB to -20dB); 5dB/20° (-20dB to -40dB)

★ For Standing Wave: ±0.15 ( VSWR < 2 ); < Effective readings x 10%±0.1 ( 2 < VSWR < 10 )

  • ★ This instrument has four interfaces: Single point Measurement, Scanning, system information, correction and calibration The default boot into single-point measurement interface.
  • ★ Note: For the convenience of the user, each time calibration correction options will automatically change to the user calibration. Meanwhile, in order to ensure the integrity of the calibration, the calibration process, the automatic shutdown function fails, the consistent boot.
  • ★ Press the second button and power button at the same to power on .
  • ★ The boot state, long press (2S above) the switch button, after the release, the instrument will shut down.
  • ★ Startup and shutdown Hold down the CTRL key off press the power switch button.
  • ★ This instrument has four interfaces: Single point Measurement, Scanning, system information, correction and calibration The default boot into single-point measurement interface.
  • ★ Note: For the convenience of the user, each time calibration correction options will automatically change to the user calibration. Meanwhile, in order to ensure the integrity of the calibration, the calibration process, the automatic shutdown function fails, the consistent boot.
  • ★ Press the second button and power button at the same to power on .
  • ★ The boot state, long press (2S above) the switch button, after the release, the instrument will shut down.
  • ★ Startup and shutdown Hold down the CTRL key off press the power switch button.

Similar Products

10pcs SMA Female 4-Hole Panel Mount Flange RF Coax Connector with Solder Cup Straight USA ShippingDGZZI 2-Pack N Male to SMA Female RF Coaxial Adapter N to SMA Coax Jack ConnectorLoRa Gateway Antenna 3dbi Gain Glass Fiber Reinforced Antenna RAK831 Connect Cable Ultra Distance Transmission 915MHz Q074SMA-UHF RF Connectors Kit SMA to UHF PL259 SO239 4 Type Set SMA Jack/Plug to UHF Nickel Gold Plated Test Converter Pack of 4 ...RF design SMA Male Plug to RP-SMA Female 2 Pieces RF coaxial Coax Adapter Coupling Nut Connector GoldenAven 17010 Adjustable Circuit Board Holder