This 3/4" water check valve is installed in the inlet side of the circulation pumps plumbing to prevent the back flow of water through the circulation pump once the jet pump is activated. All water check valves have arrows s...

Buy Now From Amazon

This 3/4" water check valve is installed in the inlet side of the circulation pumps plumbing to prevent the back flow of water through the circulation pump once the jet pump is activated. All water check valves have arrows stamped on the outside to indicate the direction of flow which should be pointer towards the circulation pump. These low flow water check valves come in two sizes (1/2" #HTCP70173 & this 3/4"). This is for a Single Watkins Water Check Valve, 3/4" OEM Replacement High Grade Quality that's made to last!! Troubling Shooting: The symptoms of a non-operative check valve are; * Water Leak - If water is leaking from around the check valve, it should be replaced. * Rattling - A rattling check valve indicates that water is not being allowed to flow properly past/ through the check valve. * Verify the check valve is installed with the flow in the correct direction. * Heater High-Limit Tripping - Poor water flow through the check valve could lead to heater high-limit tripping. Ensure the check valve is not block by debris and operating properly. * Surging jet pump (on spas equipped with a flow switch).

  • Item 35233
  • This 3/4" water check valve is installed in the inlet side of the circulation pumps plumbing to prevent the back flow of water through the circulation pump once the jet pump is activated
  • Works on Tiger River Spas, Hot Spring Spas, and Limelight Spas.
  • All water check valves have arrows stamped on the outside to indicate the direction of flow which should be pointer towards the circulation pump.
  • Troubling Shooting: The symptoms of a non-operative check valve are; * Water Leak - If water is leaking from around the check valve, it should be replaced. * Rattling - A rattling check valve indicates that water is not being allowed to flow properly past/ through the check valve. * Verify the check valve is installed with the flow in the correct direction. * Heater High-Limit Tripping - Poor water flow through the check valve could lead to heater high-limit tripping. Ensure the check valve is n
  • Item 35233
  • This 3/4" water check valve is installed in the inlet side of the circulation pumps plumbing to prevent the back flow of water through the circulation pump once the jet pump is activated
  • Works on Tiger River Spas, Hot Spring Spas, and Limelight Spas.
  • All water check valves have arrows stamped on the outside to indicate the direction of flow which should be pointer towards the circulation pump.
  • Troubling Shooting: The symptoms of a non-operative check valve are; * Water Leak - If water is leaking from around the check valve, it should be replaced. * Rattling - A rattling check valve indicates that water is not being allowed to flow properly past/ through the check valve. * Verify the check valve is installed with the flow in the correct direction. * Heater High-Limit Tripping - Poor water flow through the check valve could lead to heater high-limit tripping. Ensure the check valve is n

Similar Products

Low-Flow Titanium Heater w/Sensors for Hot Spring/Watkins/Tiger River/Limelight Hot Tub Spa No-Fault 6kWSpa Circulation Pump E5 - 74427 for Watkins: Hot Spring, Tiger River, Caldera Hot Tubs by LaingGuardian Pool Spa Filter Replaces unicel c-8465, pleatco PWK65, Filbur FC-3960 Watkins 65Hydro Flow Premium Ball Valve 3/4 Inch BarbHot Springs Heater Relay Board 77119 (Formerly 74618) IQ 2020 WatkinsUnicel C-8465 Replacement Filter Cartridge for 65 Square Foot Hot Springs Spas/Watkins MfgHot Spring Watkins Replacement Filter Standpipe Cap, Grey - 36513