Suncourt -- Inductor 6" In-Line Duct Fan With Cord (DB206-CRD) - includes installed cord with grounded plug.  Cord Length - 6 Feet.The Inductor In-Line Duct Fan solves air delivery problems without major system rework ...

Buy Now From Amazon

Suncourt -- Inductor 6" In-Line Duct Fan With Cord (DB206-CRD) - includes installed cord with grounded plug.  Cord Length - 6 Feet.The Inductor In-Line Duct Fan solves air delivery problems without major system rework or expense. Double crimped for easy flex duct installation. Duct Diameter: 6" Unit Weight: 2.0 Lbs. Max Boosted CFM: 250 Free Air CFM: 160 Amps: 0.35 Housing Length: 6" dBA: 50 Blade Type: Polycarbonate NEVER expose your Inductor to airflow temperatures exceeding 140F (60C). · Make sure all electrical wiring conforms to all applicable codes and standards. If you are not familiar with electrical installations, consult a qualified electrician. · Never use an Inductor for dryer venting. · Never connect the High and Low speed wires of a 2-speed Inductor together. Why do I have a room that is always too cold? Your problem room may be located far from the furnace. Friction in the long duct reduces airflow to the register in that room, thus delivery of heated air. Also, perhaps the room is over an unheated garage or the duct is simply too small (undersized) to get enough heated air to that room. Remember too, when you are delivering heated air to a room, that air has to have a way to get out of that room. Otherwise there will be no air circulation. Does the room have an air return register? If not, is the door of that room kept closed, stopping air circulation? Why do I have a room that is always too hot? The room that you have a cooling problem with may be far away from the central air system. Long duct runs cause reduction in airflow, plus, the cooled air may have heated up before it gets to the problem room. Perhaps the problem run is to a room on the South side of the house, which has a large window, catching a lot of summer heat. Chances are that your 'hot' rooms are on the second level of your home. You see, cooled air is dense and heavy. It doesn't like to flow upstairs. This is a very common problem, worsen

Similar Products

Suncourt DS100 DuctStat Plug-In ThermostatSuncourt Variable Speed Fan Controller SCPTjernlund PS1503 Duct Airstat Pressure SwitchWiss WC5L 5-Blade 1-5/8-Inch Depth - HVAC CrimperVenTech VT DUCT-6 VTD625 Aluminum Duct for Ventilation Ducting, 6''TerraBloom 6 Inch Air Duct, Flexible Aluminum HVAC Ducting, 25 Feet Long with 2 Clamps, 6Tjernlund M-6 Inline Duct Booster Fan, Hydroponic Blower Heat Air Conditioning Vent Exhaust, 460 CFM, 6VenTech VT IF6+CF6-B Inline Exhaust Blower Fan with Carbon Filter and Variable Speed Controller, 440 CFM, 6