Extech EX623 400A Dual Input AC/DC Clamp Meter + NCV + IR Thermometer; 40,000 count multimeter functions for DC Voltage, Resistance, Capacitance, and Frequency for high resolution over wider ranges
This TRMS AC/DC Clamp Meter has dual thermocouple inputs for T1, T2, T1-T2 Differential Temperature measurement plus a built-in Infrared Thermometer with laser pointer for locating hot spots and NCV Detector. Comes complete with test leads, 9 Volt battery, two Type K bead wire Temperature probes and carrying case.
Key Features- Data Hold plus fast Peak Hold of current surges during motor startup
- 40,000 count multimeter functions for DC Voltage, Resistance, Capacitance, and Frequency for high resolution over wider ranges
- Measures motor capacitors to 40,000µF
- 1.25" (32mm) jaw opening for conductors up to 500MCM
- Rugged double molded housing
- Auto power off with audible alert and disable function
- Autoranging with manual override
- 8 to 1 distance to target ratio
- AC/DC Current (Max Res.): 400.0A AC/DC (10mA)
- Basic ACA accuracy: ±1.5%
- AC/DC Voltage (Max Res.): 600V (0.1mV)/600V (0.01mV)
- DC µA Current (Max Res.): 4000µA (0.01µA)
- Resistance (Max Res.): 40.000MΩ (0.01Ω)
- Capacitance (Max Res.): 40mF (0.01nF)
- Frequency (Max Res.): 40MHz (0.001Hz)
- Temperature - Type K: -58 to 1832°F (-50 to 1000°C)
- Diode (2.8V)/Continuity: Yes
- Duty Cycle: 0.5 to 99.0%
- Dimensions: 9"x3.1"x1.9"
- Weight: 10.7oz